HLN-127 Neutralizing Corrosion Inhibitor for Atmospheric and Vacuum Distillation Units
Product Features
- pH Control: Maintains the pH of condensed water within 5.5 to 6.0, balancing acid corrosion and under-scale corrosion caused by NH4Cl and FeS.
- Efficient Performance: Reduces agent consumption by over 20% compared to similar products, achieving a corrosion inhibition rate of ≥90%.
- Anti-Emulsification: Minimizes the tendency of condensed water to form emulsions, lowering oil content and COD in the water phase.
- Environmentally Safe: Free of metals and harmful elements, ensuring no adverse effects on downstream processing units or wastewater treatment systems.
Technical Specifications
|
Parameter |
Technical Indicators |
Test Method |
|
Appearance |
Brown liquid |
Visual Inspection |
|
Solubility |
Miscible with water in any ratio |
Visual Inspection |
|
Density (20℃, kg/m³) |
950~1050 |
GB/T 13377 |
|
Freezing Point (℃) |
≤-20 |
GB/T 510 |
|
Kinematic Viscosity (40℃, mm²/s) |
≤20 |
GB/T 265 |
|
pH (10% aqueous solution) |
≥11.0 |
SH/T 0069 |
|
Corrosion Inhibition Rate (%) |
≥90 |
Q/SHCG109-2017Appendix A |
|
Water Content (%) |
Reported Value |
SH/T 0246 |
Applications
- Corrosion Control: Protects against HCl-H2S-H2O corrosion in overhead condensing cooling systems of atmospheric and vacuum distillation units.
- Scale Mitigation: Prevents ammonium chloride (NH4Cl) and iron sulfide (FeS) scaling, avoiding secondary corrosion and ensuring equipment longevity.
Usage Instructions
1. **Preparation:** Pump the product into a corrosion inhibitor storage tank and dilute with demineralized or deoxygenated water to the required concentration.
2. **Injection Points:** Use a metering pump to inject the inhibitor before the water injection point on the evaporation line at the top of the distillation column, ideally close to the dew point.
3. **Dosage:** Adjust injection rates to maintain the pH of condensate between 5.5 and 8.0. Typical dosage: 10-40ppm (relative to crude oil). Initial doses may be increased to establish adsorption equilibrium.
4. **Custom Adjustment:** Modify injection rates based on crude oil properties (organic chlorine and sulfur content), condensate chloride ion levels, and corrosion monitoring data.
Performance Guarantee
- Maintains iron ion concentration in condensed water at critical points (e.g., primary distillation tower, atmospheric tower, and vacuum tower tops) is ≤3mg/L.
- Does not cause emulsification or affect oil-water separation, device stability, or product quality.
- No adverse effects on downstream processing units or wastewater treatment systems.
- Recommended Dosage: Based on crude oil properties, the following table provides guidance on neutralizer injection rates.
Recommended Dosage Table
|
Organic Chlorine Content (mg/L) |
Sulfur Content (wt%) |
Recommended Injection Rate (μg/g) |
|
≤10 |
≤1.0 |
10-20 |
|
≤10 |
1.0-2.0 |
15-25 |
|
≤10 |
≥2.0 |
20-30 |
|
10-30 |
≤1.0 |
15-25 |
|
10-30 |
1.0-2.0 |
20-30 |
|
10-30 |
≥2.0 |
25-35 |
|
≥30 |
≤1.0 |
20-30 |
|
≥30 |
1.0-2.0 |
25-35 |
|
≥30 |
≥2.0 |
30-40 |
Packaging, Storage, and Safety
- Packaging: Available in 25L plastic drums, 200L iron or plastic drums, or IBC ton barrels.
- Storage: Store in a cool, dry, and ventilated area at room temperature. Shelf life: 2 years.
- Safety: Keep away from fire sources. Refer to the Material Safety Data Sheet (MSDS) for additional safety information.